Search results for "Safety criteria"

showing 3 items of 3 documents

Management of returned anti-neoplastic treatments and their reuse in oncology patients

2009

Abstract Objective Analyse the profile of parenteral preparation and treatment (anti-neoplastic and supplementary) that were dispensed and returned to the Pharmacy Department, the reasons why they were not administered, their reuse and the associated direct costs. Method Longitudinal study over 8 months (October 2004-May 2005) in a tertiary hospital with centre for preparing anti-neoplastic agents (including supplementary treatment) in its Pharmacy Department. The variables studied, downloaded from the Oncofarm® application, are as follows: a) patients and diagnostics; b) returned treatments, classified by reason returned, pharmaco-therapeutic scheme, cycle, and day; c) returned preparation…

Indirect costsmedicine.medical_specialtybusiness.industryInternal medicineSafety criteriaMedicineOncology patientsPharmacybusinessAnti neoplasticLevofolinic acidConfidence intervalFarmacia Hospitalaria (English Edition)
researchProduct

Gestión de la devolución de tratamientos antineoplásicos y de su reutilización en pacientes oncológicos

2009

Objective: Analyse the profi le of parenteral preparation and treatment (anti-neoplastic and supplementary) that were dispensed and returned to the Pharmacy Department, the reasons why they were not administered, their reuse and the associated direct costs. Method: Longitudinal study over eight months (October 2004-May 2005) in a tertiary hospital with centre for preparing anti-neoplastic agents (including supplementary treatment) in its Pharmacy Department. The variables studied, downloaded from the Oncofarm® application, are as follows: a) patients and diagnostics; b) returned treatments, classifi ed by reason returned, pharmaco-therapeutic scheme, cycle and day; c) returned preparations …

Pharmacologymedicine.medical_specialtyIndirect costsbusiness.industryInternal medicinemedicineSafety criteriaPharmacybusinessLevofolinic acidSurgeryFarmacia Hospitalaria
researchProduct

Structural analysis of the back supporting structure of the DEMO WCLL outboard blanket

2017

Abstract Within the framework of EUROfusion R&D activities an intense research campaign has been carried out at the University of Palermo, in close cooperation with ENEA Brasimone, in order to investigate the thermo-mechanical performances of the outboard segment Back-Supporting Structure (BSS) of the DEMO Water-Cooled Lithium Lead breeding blanket (WCLL). In particular, the configuration of the outboard segment BSS, purposely set-up by the WCLL project team during 2015 according to the blanket “multi-module system” concept, has been taken into account in order to study its steady state thermo-mechanical behaviour, paying attention to the simulation of both modules-BSS and BSS-vacuum vessel…

Structure (mathematical logic)business.industryComputer scienceMechanical EngineeringDEMO reactor WCLL blanket BSSDEMO reactorStructural engineeringBlanket01 natural sciencesProject teamFinite element method010305 fluids & plasmasWCLL blanketGeometric designNuclear Energy and EngineeringLinearization0103 physical sciencesSafety criteriaGeneral Materials Science010306 general physicsbusinessBSSSettore ING-IND/19 - Impianti NucleariCivil and Structural EngineeringFusion Engineering and Design
researchProduct